CMUOD-100-1500A
CMUOD-100-1500A
Features:
- LCD-display
- Microprocessor control
- Case type (RACK) for installation in the rack cabinet
- Wide operating temperature range from -40 ∞ C to 80 ∞ C.†UPS suitable for† outdoor use
- Support UPS operating mode of the DSU
- Pure sine output
- Various line-up of outlets
- UPS On-line class
- PF - 0.8
- On Self Test
- Cold start
- Microprocessor control
- Wide input voltage range
- Adjustable battery charge current
- Signal programming function for dry contacts (AS-400)
- Protection against short-circuit, overload and other interference in the input power
- Charge the battery when the UPS is off
- Connecting additional battery kakbinetov
- The presence of EPO plugs for quick emergency power off
- Availability management ports: USB, RS-232, SNMP
Vertriebspartner
|
|
Technology
UPS Type |
On-line |
execution
Form Factor |
Installation in 19 '' rack (Rack) |
Number of phases
Specification |
1 phase input to ground with ground and 1-phase output from the ground |
Input parameters
Power |
1500VA / 1200W |
Input voltage |
220/230/240 |
Input voltage range |
170 - 300 |
Current frequency |
50/60 Hz (auto sensing) |
Phases |
one phase grounding |
Output parameters
Output voltage |
220/230/240 V ± 1% |
Form voltage |
pure sine wave |
Current frequency |
50/60 Hz ± 0,1% |
Automatic voltage regulation (AVR) |
Yes |
switching time |
12 ms |
Power factor correction |
0,8 |
Harmonic voltage fluctuations |
<3% |
Crest factor |
3:1 |
Protection and UPS equipment
Surge Protection |
Yes |
Overload protection |
Yes |
UPS Login |
Circuit breaker |
Short circuit |
Immediate load shedding or tripping of upstream circuit breaker |
Protect the phone, fax, modem, LAN |
No |
Ports and interfaces
USB-port |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
RS-232 |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
Port emergency shutdown EPO |
Yes |
SNMP |
Built-in expansion slot for SNMP adapter |
Connections of the generator input |
Yes |
Parallel UPS connection |
No |
Dry contacts |
Yes |
Battery
A type |
Lead-acid, sealed, maintenance-free |
Voltage and battery capacity |
12V / 9AH x 2 |
Typical recharge time |
6 hours (up to 90% of full battery capacity) |
Charging Current (Max) |
2A - 10A |
Estimated battery backup time (at 50% load) |
- |
Estimated battery backup time (at 100% load) |
- |
Hot-swappable batteries |
No |
Connecting additional battery cabinets |
Yes |
Cold start |
Yes |
battery protection |
Automatic diagnostics, protection against overcharge and short-circuit |
Physical parameters
Output connectors |
- |
Dimensions (W * D * B) mm |
400x240x133 3U |
Weight, kg |
12,5 |
Indication |
LED and LCD-display (input / output voltage, frequency input / output voltage Operating modes: normal, bypass, battery power, battery level, load level) |
Sound alarm |
Beep in battery mode, when the battery is low, overload and fault charger |
Case features
Material |
Metal (0.5 mm) |
protection class |
IP20 |
Environmental Parameters
Acoustic noise |
<48 dB (at 1 meter from surface) |
Working conditions |
Humidity 5 ~ 95% non-condensing, temperature -40 to + 80? C |
Guarantee
standard warranty |
1 year |
Der gesamte Katalog
Acoustics & Multimedia
IT Peripherals
Cartridges
UPS
Corporate solutions

Österreich
Kroatien
England
Kasachstan
Spanien
Tschechien
Frankreich
Polen
Türkei
Bulgarien
Deutschland
Deutschland
Italien
Ukraine
Ukraine
Russland
Weissrussland
USA
Kanada
Kuweit
Libanon
Saudi Arabien
VAE
Algerien
Kenia
Nigeria
Südafrika
China
Pakistan
Australien
China
Indien 




































Speakers 2.1
Bluetooth speakers
Digital consoles
Data cables
Charging device
Accumulator battery